LANmark-MD537 Cat 5e Solid Shielded TPE

Description
Berk-Tek LANmark Industrial Medium-Duty (MD) Ethernet Cables enable the expansion and integration of Ethernet into the Industrial environment. With over 50 years of manufacturing expertise, you can be sure these Industrial Cables will perform both mechanically and electrically. With its 600V AWM design, durable TPE jacket, cold-bend performance, and resistance to oil, weld spatter, and sunlight, this cable is suitable for demanding , static, industrial applications. Additionally, this product has both a foil shield and a braid to protect against low- and high-frequency noise on the factory floor. It is rated CMR and CMX Outdoor, so it easily transitions from indoor to outdoor environments and is also suitable for cable tray installations.
Description
Standards
International : ISO/IEC 11801National : ANSI/TIA-568-C.2; UL 444
Description
Construction
24 AWG solid tinned copper wire insulated with HDPE. Two insulated conductors twisted together to form a pair and four such pairs to form the basic unit, enclosed by polyester tape, and shielded with aluminum/polyester tape (aluminum facing out). Drain wire and 80% optical coverage braid contained within TPE jacket.
Related Standards
Low Voltage - EU Directive 2014/35/EU, CE Approved
RoHS - EU Directive 2011/65/EU
PoE+ - Type 2 (802.3at)
Ratings | ||
---|---|---|
Description | Method | |
Listed Type | UL1666 | CMR |
Listed Type | UL444 | CMX Outdoor |
Oil Resistance | UL1277 11.2 | II (75°C) |
Sunlight Resistance | UL444 7.22 | Yes (720 hrs) |
Attributes | ||
---|---|---|
Description | Method | |
AWM Style | UL758 | 2463 (600V, 80°C) |
Cold Bend | UL444 7.10 | -40°C |
Weld Spatter Resistance | Internal (SOP 58.8.12) | Yes |
Installation Pull Tension (Max): | ||
Bend Radius: > 3 inch | Internal | 40 lbs. |
Bend Radius: > 1.16 inch | TIA 568-C.0 | 25 lbs. |
Abrasion | UL2556 7.10 | 75 cycles/1.5 lb. load |
Characteristics
Construction characteristics | |
---|---|
Conductor material | 24 AWG Tinned Copper |
Insulation | HDPE |
Jacket Material | TPE |
Braid | Tinned copper - 80% optical coverage |
Shielding | Aluminum/Polyester |
Core Tape | Polyester |
Drain wire | Stranded Tinned Copper 7/32 |
Dimensional characteristics | |
Insulated conductor diameter (Nominal) | 0.046in |
Average jacket thickness | 0.03in |
Minimum jacket thickness at any point | 0.024in |
Cable diameter (Nominal) | 0.29in |
Nominal cable weight | 44lb/kft |
Length per reel | 1000.0ft |
Electrical characteristics | |
Mutual capacitance | 5.6 nF/100m max. |
DC Resistance (max.) | 9.38Ohm/100m |
DC resistance unbalance (max.) | 5% |
Nominal velocity of propagation | 66% |
Maximum pair to ground unbalance | 330pF/100m |
Transfer impedance | Grade 2 |
Transmission characteristics | |
Skew (max.) | 45ns/100m |
Usage characteristics | |
Minimum Bending Radius - Install | 2.32in |
Recommended installation temperature range | -20 .. 80°C |
Recommended operating temperature range | -40 .. 80°C |
Recommended storage temperature range | -40 .. 80°C |
Specific characteristics | |
See all products | |
|
Products and services
Docs and info
-
Technical Information
Electrical Characteristics Parameter Frequency Equation RL (dB) 1-10 MHz 20+5*Log(F) 10-20 MHz 25 20-100 MHz 25-7*Log(F/20) Insertion Loss (dB/100m) 1-100 MHz 1.967*√F+0.023*F+0.050/√F NEXT (dB) 1-100 MHz 35.3-15*Log(F/100) PS-NEXT (dB) 1-100 MHz 32.3-15*Log(F/100) ACR (dB/100m) 1-100 MHz NEXT - Insertion Loss PS-ACR 1-100 MHz PS-NEXT - Insertion Loss ACRF (dB) 1-100 MHz 23.8-20*Log(F/100) PSACRF (dB) 1-100 MHz 20.8-20*Log(F/100) Propagation Delay 1-100 MHz 537+(36/√F) Max Transfer Impedance (mΩm) 1; 10; 30; 100 MHz 50; 100; 200; 1000 Min Coupling Attenuation (dB/100m) 30-100 MHz 55 Transmission Characteristics Description ISO/IEC 11801 Category 5 ANSI/TIA-568-C.2 Category 5e Coupling Attenuation IEC 61156-5 Type II Transfer Impedance IEC 61156-5 Grade 2 Color Code Pair-1 White/Blue Blue Pair-2 White/Orange Orange Pair-3 White/Green Green Pair-4 White/Brown Brown