Datacenter Plenum Indoor (DAP8B)

Description
Berk-Tek’s revolutionary Datacenter Plenum cables with 1.9 mm micro buffer tubes are designed to be used in high density plenum rated environments. DAP is rated for plenum installations and has no gel filler.

Description
Standards
International : EN 50173; ISO/IEC 11801National : ANSI/ICEA S-83-596; ANSI/TIA-568.3-D; NFPA 130; Telcordia GR-409
Description
Berk-Tek's loose tube cable design can be used in all typical campus indoor installations, and is available with standard multimode, single-mode and GIGAlite™ fibers. Datacenter Plenum cable is available in 1 to 288 count fiber constructions. These cables have been thoroughly tested in accordance with Telcordia GR-409 Issue 2, and ICEA-596 Edition 3, where applicable.
These cables are compliant with the Wire and Cable Requirements of NFPA 130 (2014), section 12.2 Flame Spread and Smoke Release. They are suitable for railway and mass transit infrastructure in tunnels, as well as for Tray installations in industrial environments.
Buffer Tube Construction
Dry color coded loose tubes containing up to 8, 250 µm, individually colored fibers.
Applications
Berk-Tek's Datacenter Plenum Loose Tube fiber optic cable is intended for all high speed data applications, including:
- ETHERNET: 10BASE – 400GBASE (10BASE, 100BASE, 1000BASE, 10GBASE, 40GBASE, 100GBASE, 400GBASE)
- Fibre Channel: 1G-FC – 128GFC (1, 2, 4, 8, 16, 32, 128 GFC)
- SONET: OC-1 – OC-768 (OC -1, 3, 12, 24, 48, 192, 768)
- SDH: STM-0 – STM-256 (STM-0, 1, 4, 16, 64, 256)
- OTN: OTU-1 – OTU4 (OTU1, 2, 2e, 2f, 3, 3e2, 4)
- CPRI: CPRI-1 – CPRI-9 (CPRI-1, 2, 3, 4, 5, 6, 7, 7a, 8, 9)
- PON (SMF ONLY): RFoG, APON, BPON, EPON, GPON, WDM-PON, NG-PON
Features
- 1.9 mm space saving buffer tubes housing fibers and aramid strength yarns
- Designed to support Gigabit Ethernet, Gigabit ATM, Fibre Channel and other high-speed applications
- Plenum rating enables installation to go directly through plenum spaces
- All dielectric design
Benefits
- Compact, plenum rated, flexible loose tube design of all dielectric construction allows for installation in any interior space
- Optimized access ease with simple, off-the-shelf tools
- No cleaning of gels required for installation, greatly reducing installation time and cost
- System grounding requirements are eliminated
Country of Origin: U.S.A.
Characteristics
Construction characteristics | |
---|---|
Type of cable | Loose tube |
Jacket Material | Plenum |
Usage characteristics | |
Recommended operating temperature range | 0 .. 75°C |
Ambient installation temperature, range | 0 .. 60°C |
Recommended storage temperature range | -40 .. 75°C |
Specific characteristics | |
See all products | |
|
Products and services
Docs and info
-
Standard Sheath Colors - Loose Tube
-
Manufacturing Release
IMPORTANT NOTICE: This product specification is provided for informational purposes only in order to illustrate typical product constructions, applications and/or methods of installation. Because conditions of actual installation and use are unique and will vary, Berk-Tek makes no representation or warranty as to the reliability, accuracy or completeness of this data, even if Berk-Tek is aware of the product's intended use or purpose. Furthermore, this data does not constitute, nor should it be regarded or relied upon, as professional engineering advice. Installation of product should only be done by qualified personnel and in conformance with all safety, electrical and other applicable codes, standards, rules or regulations. Appropriate and correct product selection, installation and use, and compliance with all such codes, standards, rules and regulations, is a customer/end-user responsibility. Product specifications, standards, programs or services are subject to improvement or changes without notice. Berk-Tek accepts no liability for typographical errors, technical inaccuracies, omissions or misuse of the information contained herein. Changes will be periodically made to address any such issues.