Description
Standards
International : ISO/IEC 11801National : ANSI/TIA 568.2-D; UL 444
Description
Construction
24 AWG stranded tinned stranded copper wire insulated with polyethylene. Two insulated conductors twisted together to form a pair and four such pairs laid up with crossfiller to form the basic unit jacketed with flame-retardant PVC.
Standards
- North American: ANSI/TIA-568.2-D, UL 444 &C22.2 No.214-02
- International: ISO/IEC 11801-1995 Category 6, EU Directive 2011/65/EC (RoHS)
Flame Rating
- Patch-UL 1685, CM, IEC 332-1
- UL Listed
Features
- Full duplex operation capable over four cable pairs
- Increased usable bandwidth vs. the category 6 standard
- Documented balance characteristics (LCL/TCL, EL TCTL)
- ETL verified to ANSI/TIA-568.2-D standard
Benefits
- Provides additional performance margin to reliably support Gigabit Ethernet in high-noise environments
- Provides bandwidth required for multimedia, broadband video analog video and other future applications
- Balance characteristics improve overall cable performance and reduce cable emissions which results in reduced transmission errors
PROUDLY MADE IN THE USA
Characteristics
Construction characteristics | |
---|---|
Type of cable | UTP |
Colour | Green |
Dimensional characteristics | |
Length per reel | 1000.0ft |
Number of pairs | 4 |
Usage characteristics | |
Packaging | Reel |
Field of application | Indoor |
Category | Cat. 6 |
Fire safety | CM |
Docs and info
Technical Data - Physical
Technical Data - Physical |
|
Color Code |
||||
|
Pair-1 |
White/Blue |
Blue |
|||
Conductor |
24 AWG stranded TC |
Pair-2 |
White/Orange |
Orange |
||
Conductor diameter–in. (mm) |
0.024 |
(0.64) |
Pair-3 |
White/Green |
Green |
|
insulated conductor diamater |
0.040 |
(1.02) |
Pair-4 |
White/Brown |
Brown |
|
Cable diameter–in. (mm) |
0.240 |
(6.27) |
|
|||
Nominal cable weight–lb./kft. (kg/km) |
28 |
(42) |
Temperature Rating |
|||
Max. installation tension–lb. (N) |
25 |
(110) |
Installation |
0°C to +50°C |
||
Min. bend radius–in. (mm) |
1.00 |
(25.4) |
Operation |
-20°C to +75°C |
Technical Data - Parametric Measurements
Mutual Capacitance |
5.3 nF/100m nom. |
DC resistance max. |
9.09 Ohms/100 m max. |
Skew |
45 ns/100 m max |
Pair to ground Unbalance |
330 pF/100 m max. at 1 kHz |
Velocity of Propagation |
67% nom. |
DC Resistance Unbalance |
5% max. |
Technical Data - Electrical
Freq |
SRL |
RL |
IL |
PS-NEXT |
NEXT |
ACR |
PS-ACR |
ACRF |
PS-ACRF |
LCL/TCL |
EL TCTL |
min. |
min. |
max. |
min. |
min. |
min. |
min. |
min. |
min. |
min. |
min. |
|
1 |
26.0 |
20.0 |
2.4 |
78.3 |
80.3 |
77.9 |
75.9 |
72.8 |
72.8 |
50.0 |
35.0 |
4 |
26.0 |
23.6 |
4.5 |
69.3 |
71.3 |
66.8 |
64.8 |
60.7 |
60.7 |
44.0 |
23.0 |
10 |
26.0 |
26.0 |
7.1 |
63.3 |
65.3 |
58.2 |
56.2 |
52.8 |
52.8 |
40.0 |
15.0 |
16 |
26.0 |
26.0 |
9.0 |
60.3 |
62.3 |
53.3 |
51.2 |
48.7 |
48.7 |
38.0 |
10.9 |
20 |
26.0 |
26.0 |
10.1 |
58.8 |
60.8 |
50.7 |
48.7 |
46.7 |
46.7 |
37.0 |
9.0 |
31.25 |
25.1 |
25.1 |
12.7 |
55.9 |
57.9 |
45.2 |
43.2 |
42.9 |
42.9 |
35.1 |
— |
62.5 |
23.5 |
23.5 |
18.3 |
51.4 |
53.4 |
35.1 |
33.0 |
36.8 |
36.8 |
32.0 |
— |
100 |
22.5 |
22.5 |
23.6 |
48.3 |
50.3 |
26.7 |
24.7 |
32.8 |
32.8 |
30.0 |
— |
250 |
20.5 |
20.5 |
39.2 |
42.3 |
44.3 |
5.1 |
3.2 |
24.8 |
24.8 |
26.0 |
— |
350 |
19.8 |
19.8 |
47.4 |
40.2 |
42.2 |
— |
— |
21.9 |
21.9 |
— |
— |
400 |
19.0 |
19.5 |
51.2 |
39.3 |
41.3 |
— |
— |
20.7 |
20.7 |
— |
— |
500 |
18.6 |
19.0 |
58.3 |
37.8 |
39.8 |
— |
— |
18.8* |
18.8* |
— |
— |
* Values provided for reference only |
|||||||||||
-
Supported Category 6 Applications
STANDARD APPLICATION SPEED IEEE 802.3 1000BASE-T 1 Gb/s TIA/EIA-854 1000BASE-TX 1 Gb/s ATM 155Mb/s 155 Mb/s IEEE 802.3 100BASE-TX 100 Mb/s CDDI 100 Mb/s IEEE 802.3 10BASE-T 10 Mb/s
IEEE 802.3 af PoE 1 Gb/s IEEE 802.3 at PoE+, Type 1 & 2 1 Gb/s