Description
Standards
International : EN 50173; ISO/IEC 11801National : ANSI/ICEA S-83-596; ANSI/TIA-568.3-D; NFPA 130; Telcordia GR-409
Description
Berk-Tek's Plenum Micro-Interconnect Tight Buffered cables are available with standard multimode, single-mode, and GIGAliteTM optical fibers.
Construction
600 um or 900 um buffered fibers surrounded by aramid yarns. Sheathed using a special state-of-the-art, polymer material.
All Dielectric. OFNP FT-6
Applications
Berk-Tek's Micro-Interconnect Tight Buffered Cable is intended for all high speed data applications including:
- ETHERNET: 10BASE – 400GBASE (10BASE, 100BASE, 1000BASE, 10GBASE, 40GBASE, 100GBASE, 400GBASE)
- Fibre Channel: 1G-FC – 128GFC (1, 2, 4, 8, 16, 32, 128 GFC)
- SONET: OC-1 – OC-768 (OC -1, 3, 12, 24, 48, 192, 768)
- SDH: STM-0 – STM-256 (STM-0, 1, 4, 16, 64, 256)
- OTN: OTU-1 – OTU4 (OTU1, 2, 2e, 2f, 3, 3e2, 4)
- CPRI: CPRI-1 – CPRI-9 (CPRI-1, 2, 3, 4, 5, 6, 7, 7a, 8, 9)
- PON (SMF ONLY): RFoG, APON, BPON, EPON, GPON, WDM-PON, NG-PON
Features
- Flexible, small diameter, 600 um or 900 um tight buffered construction
- High tensile strength and small diameter design
- 1 and 2 fiber designs for patch cable installations
Country of Origin: U.S.A.
Characteristics
Construction characteristics | |
---|---|
Fiber optic type | SM (G657.A1) |
Type of cable | Tight Buffered (TB) |
Jacket Material | Plenum |
Sheath colour | Yellow |
Dimensional characteristics | |
Tube diameter | 1.6mm |
Number of optical fibres | 1 |
Cable diameter (Nominal) | 0.063in |
Nominal outer diameter | 1.6mm |
Nominal cable weight | 2lb/kft |
Approximate weight | 3kg/km |
Transmission characteristics | |
Optical performance | AB (Single-mode, OS2) |
Attenuation, max. 1310 nm (cabled) | 0.5dB/km |
Attenuation, max. 1550 nm (cabled) | 0.5dB/km |
Mechanical characteristics | |
Maximum installation tension | 25lb |
Maximum installation tension | 111N |
Max. Load. Long Term (lbs) | 8.0lb |
Max. Load. Long Term | 33.0N |
Impacts per TIA/EIA FOTP-25 | 2 at 0.50 N-m |
Crush resistance per TIA/EIA FOTP-41 | 100N/cm |
Cable flexibility per TIA/EIA FOTP-104 | 100 cycles |
Usage characteristics | |
Minimum Bending Radius - Install | 0.9in |
Minimum Bend Radius - Install | 2.4cm |
Minimum Bending Radius - LongTerm | 0.6in |
Minimum Bending Radius - LongTerm | 1.6cm |
RoHS compliant | Yes |
Recommended operating temperature range | -20 .. 75°C |
Ambient installation temperature, range | 0 .. 70°C |
Recommended storage temperature range | -40 .. 85°C |
Field of application | Indoor |
Docs and info
Standard Sheath Colors
Fiber Type |
Core |
ISO-TIA |
Effective Modal |
Overfilled Launch |
Attenuation |
Attenuation |
Attenuation |
Sheath Color |
AB |
8.3 |
OS2 |
NS |
NS |
NS |
0.5 dB/km |
0.5 dB/km |
Yellow |
CB |
62.5 |
OM1 |
200 MHz-km |
200 MHz-km |
3.5 dB/km |
1.0 dB/km |
NS |
Orange |
EB |
50 |
OM3 |
2000 MHz-km |
1500 MHz-km |
3.0 dB/km |
1.0 dB/km |
NS |
Aqua |
FB |
50 |
OM4 |
4700 MHz-km |
3500 MHz-km |
3.0 dB/km |
1.0 dB/km |
NS |
Aqua |
XB |
50 |
OM4+ |
4900 MHz-km |
3675 MHz-km |
3.0 dB/km |
1.0 dB/km |
NS |
Violet |
WB |
50 |
OM5 |
4700 MHz-km |
3500 MHz-km |
3.0 dB/km |
1.0 dB/km |
NS |
Lime Green |
NS = Not Specified |
-
Cross-section Diagram - MCP001-1.6 mm
-
Manufacturing Release
IMPORTANT NOTICE: This product specification is provided for informational purposes only in order to illustrate typical product constructions, applications and/or methods of installation. Because conditions of actual installation and use are unique and will vary, Berk-Tek makes no representation or warranty as to the reliability, accuracy or completeness of this data, even if Berk-Tek is aware of the product's intended use or purpose. Furthermore, this data does not constitute, nor should it be regarded or relied upon, as professional engineering advice. Installation of product should only be done by qualified personnel and in conformance with all safety, electrical and other applicable codes, standards, rules or regulations. Appropriate and correct product selection, installation and use, and compliance with all such codes, standards, rules and regulations, is a customer/end-user responsibility. Product specifications, standards, programs or services are subject to improvement or changes without notice. Berk-Tek accepts no liability for typographical errors, technical inaccuracies, omissions or misuse of the information contained herein. Changes will be periodically made to address any such issues.